Submit your papersSubmit Now
For Enquiries: [email protected]
IIARD LogoIIARD

Structural Controls on Groundwater Potential and Vulnerability to Contamination in Suleja and Environs, North-Central Nigeria: Insights from Aeromagnetic, SRTM and in Situ Water-Quality Data

A. O Jegede, N.N Abdulsalam,, T.O Adeeko, O. Olasehinde

Abstract

Groundwater in crystalline basement terrains is held in thin weathered and fractured rock, so geological structure controls both where water occurs and how readily contaminants reach it. This study maps the structural controls on groundwater in part of Sheet 186 , around Suleja in North-Central Nigeria (about 22 × 24 km), and rates the vulnerability of the resulting zones to contamination. Aeromagnetic data were reduced to the equator and enhanced with first and second vertical derivatives, the analytic signal and the tilt derivative, then combined with a 30 m SRTM elevation model (209 to 554 m). The basement is densely fractured in the west, north-west and south-west, and five lineament sets were identified (N–S to NNE–SSW, NNW–SSE, WNW–ESE, ENE–WSW and E–W). Six groundwater potential zones were ranked from this framework. In situ measurements at four hand-dug wells (2.6 to 5.7 m deep), one borehole and four river points show a median well TDS of 951 mg/L, a median well conductivity of 1,562 μS/cm and a median well turbidity of 35.5 NTU, against guideline values of 500 mg/L, 1,000 μS/cm and 5 NTU. All redox potentials are positive (174 to 268 mV), indicating oxidizing conditions. The south-western basin, the west-central fracture corridor and the south-eastern lowland combine high yield potential with high vulnerability. The central corridor and the margins of the magnetic highlands are moderately vulnerable, and the northeastern high ground is a recharge area of low to moderate vulnerability. Borehole sites should meet at least three of four structural indicators and be paired with casing, well protection and seasonal monitoring.

Keywords

groundwater vulnerability; structural control; aeromagnetic data; lineaments; Basement Complex; SRTM; in situ water quality; Suleja; Nigeria

References

Ajibade, A. C., & Wright, J. B. (1989). The Togo–Benin–Nigeria Shield: evidence of crustal aggregation in the Pan-African belt. Tectonophysics, 165, 125–129. Akano, O. J., Idris-Nda, A., & Waziri, S. H. (2016). Geology and hydrogeology of part of Suleja, North Central Nigeria. Journal of Scientific Research and Reports, 9(5), 1–15. Ayoade, J. O. (2004). Introduction to Climatology for the Tropics (2nd ed.). Spectrum Books, Ibadan. Blakely, R. J. (1995). Potential Theory in Gravity and Magnetic Applications. Cambridge University Press. Dewandel, B., Lachassagne, P., Wyns, R., Maréchal, J. C., & Krishnamurthy, N. S. (2006). A generalized 3-D geological and hydrogeological conceptual model of granite aquifers controlled by single or multiphase weathering. Journal of Hydrology, 330(1–2), 260– 284. Grant, N. K. (1969). The Late Precambrian to Early Paleozoic Pan-African orogeny in Ghana, Togo, Dahomey and Nigeria. Geological Society of America Bulletin, 80, 45–56. Hem, J. D. (1970). Study and Interpretation of the Chemical Characteristics of Natural Water (2nd ed.). U.S. Geological Survey Water-Supply Paper 1473. Igboama, W. N., Hammed, O. S., Fatoba, J. O., et al. (2022). Review article on impact of groundwater contamination due to dumpsites using geophysical and physiochemical methods. Applied Water Science, 12, 130. https://doi.org/10.1007/s13201-022-01653- z Kearey, P., Brooks, M., & Hill, I. (2002). An Introduction to Geophysical Exploration (3rd ed.). Blackwell Science. [Key and Pitfield (2009): full reference to be completed by the authors.] McMahon, P. B., & Chapelle, F. H. (2008). Redox processes and water quality of selected principal aquifer systems. Ground Water, 46(2), 259–271. Miller, H. G., & Singh, V. (1994). Potential field tilt: a new concept for location of potential field sources. Journal of Applied Geophysics, 32(2–3), 213–217. Nabighian, M. N. (1972). The analytic signal of two-dimensional magnetic bodies with polygonal cross-section: its properties and use for automated anomaly interpretation. Geophysics, 37, 507–517. Obaje, N. G. (2009). Geology and Mineral Resources of Nigeria. Springer, Berlin. Ogezi, A. E. O. (1977). Geochemistry and geochronology of basement rocks from northwestern Nigeria (Unpublished PhD thesis). University of Leeds. Olorunfemi, M. O., & Fasuyi, S. A. (1993). Aquifer types and the geoelectric/hydrogeologic characteristics of part of the central basement terrain of Nigeria (Niger State). Journal of African Earth Sciences, 16(3), 309–317. Rahaman, M. A. (1988). Recent advances in the study of the basement complex of Nigeria. In Precambrian Geology of Nigeria (pp. 11–43). Geological Survey of Nigeria, Kaduna. Rajagopalan, S. (2003). Analytic signal vs. reduction to pole: solutions for low magnetic latitudes. Exploration Geophysics, 34(4), 257–262. Roest, W. R., Verhoef, J., & Pilkington, M. (1992). Magnetic interpretation using the 3-D analytic signal. Geophysics, 57(1), 116–125. Verduzco, B., Fairhead, J. D., Green, C. M., & MacKenzie, C. (2004). New insights into magnetic derivatives for structural mapping. The Leading Edge, 23(2), 116–119. Wright, E. P. (1992). The hydrogeology of crystalline basement aquifers in Africa. In E. P. Wright & W. G. Burgess (Eds.), Hydrogeology of Crystalline Basement Aquifers in Africa (Geological Society Special Publication 66, pp. 1–27).