Submit your papersSubmit Now
For Enquiries: [email protected]
IIARD LogoIIARD

Integrated Geophysical and Hydrochemical Assessment of Groundwater Quality Near Urban Dumpsites in Port Harcourt, Nigeria

Celestine Gwunmitop Idaso, Prof. I. Tamunobereton-ari, Prof. A. R. C. Amakiri

Abstract

Open dumpsites may affect groundwater quality where permeable overburden permits surface- derived solutes to enter aquifer materials. This study integrated vertical electrical sounding , electrical resistivity tomography , and borehole hydrochemical analysis at Eliozu, Rumuolumeni, and Iwofe in Port Harcourt, Nigeria. Seventeen VES stations and thirteen ERT profiles characterised subsurface resistivity structure and geoelectric protective capacity, while six borehole samples were analysed for physicochemical, microbial, heavy-metal, groundwater- quality-index , and hydrochemical-facies indicators. Conductive anomalies occurred at shallow to intermediate depths, including intervals extending to 33.40 m at Iwofe. Longitudinal conductance ranged from 0.001877 to 0.023766 S, placing all VES points in the poor class of the adopted protective-capacity rating. Reported GQI values were 126.72, 163.71, and 198.88 for the near-dumpsite boreholes and 35.94, 36.18, and 36.35 for the control boreholes. Higher reported phosphate, nitrate, iron, lead, and cadmium concentrations at near-dumpsite locations, together with an alkali–chloride facies tendency, are consistent with poorer measured groundwater quality. The results from the integrated geophysical and hydrochemical investigation of shallow aquifers around Eliozu, Rumuolumeni and Iwofe, demonstrate that groundwater within the dumpsite impacted zones has been affected by leachate infiltration.

Keywords

Electrical resistivity tomography; groundwater quality index; hydrochemical facies; leachate; vertical electrical sounding

References

[1] Christensen, T. H., Kjeldsen, P., Bjerg, P. L., Jensen, D. L., Christensen, J. B., Baun, A., Albrechtsen, H.-J., & Heron, G. (2001). Biogeochemistry of landfill leachate plumes. Applied Geochemistry, 16(7–8), 659–718. [2] Aladejana, J. A., Adeoti, L., & Ajibade, O. (2021). Leachate impact of solid waste dumpsites on groundwater quality in Nigeria: A review. Heliyon, 7(9), e08072. [3] Agbemuko, O. S., Tamunobereton-Ari, I., & Ngah, S. A. (2017). Determination of the effect of dumpsites on aquifer at Port Harcourt Metropolis, Rivers State, Nigeria. IOSR Journal of Applied Physics, 9(6), 41–54. [4] Nwankwo, C. N., & Ogoro, M. (2020). Geophysical investigation of the impact of solid waste dump on subsurface soil and groundwater in Eneka, Rivers State, Nigeria. GeoScience Engineering, 66(3), 121–135. [5] Ehirim, C. N., Ebeniro, J. O., & Ogwu, D. A. (2009). A geophysical and hydro-physiochemical study of the contaminant impact of a solid waste landfill in Port Harcourt Municipality, Nigeria. Pacific Journal of Science and Technology, 10(2), 596–603. [6] Tamuno, W., & Inichinbia, S. (2019). Vertical electric sounding of leachate contaminant plumes at a dumpsite in Obigbo, Rivers State, Nigeria. Journal of Applied Sciences and Environmental Management, 23(12), 2245–2249. [7] Ogbonna, V. A., Nwankwoala, H. O., & Lawal, O. (2017). Impacts of landfill on groundwater quality in Eligbolo-Eliozu, Obio/Akpor Local Government Area, Rivers State, Nigeria. International Journal of Emerging Engineering Research and Technology, 5(1), 20–27. [8] Ayolabi, E. A., Folorunso, A. F., & Kayode, O. T. (2013). Integrated geophysical and geochemical methods for environmental assessment of a municipal dumpsite in Lagos, Nigeria. Journal of Applied Sciences and Environmental Management, 17(4), 503–507. [9] ABEM Instrument. (2010). ABEM instruction manual: Terrameter SAS 4000 / SAS 1000. [10] Oladapo, M. I., Akintorinwa, O. J., & Olorunfemi, M. O. (2004). Geoelectric investigation of the Ondo State Housing Corporation Estate, Nigeria. Journal of Mining and Geology, 40(1), 41–48. [11] Ibanga, J. I., & George, N. J. (2016). Estimating geohydraulic parameters, protective strength, and corrosivity of hydrogeological units: A case study of ALSCON, Ikot Abasi, Southern Nigeria. Arabian Journal of Geosciences, 9, 363. [12] American Public Health Association, American Water Works Association, & Water Environment Federation. (2005). Standard methods for the examination of water and wastewater (21st ed.). American Public Health Association. [13] Patel, D. D., et al. (2023). Application of the Weighted Arithmetic Water Quality Index method for groundwater assessment. Water, 15(19), 3512. [14] United Nations Environment Programme, & International Solid Waste Association. (2024). Global Waste Management Outlook 2024: Beyond an age of waste—Turning rubbish into a resource. United Nations Environment Programme. https://doi.org/10.59117/20.500.11822/44939 [15] World Health Organization. (2022). Guidelines for drinking-water quality: Fourth edition incorporating the first and second addenda. World Health Organization. https://www.who.int/publications/i/item/9789240045064 [16] American Public Health Association, American Water Works Association, & Water Environment Federation. (2023). Standard methods for the examination of water and wastewater (24th ed.). APHA Press. IIARD International Journal of Geography & Environmental Management [17] International Organization for Standardization. (2018). ISO 5667-3:2018: Water quality— Sampling—Part 3: Preservation and handling of water samples. ISO. [18] U.S. Environmental Protection Agency. (2002). Ground-water sampling guidelines for Superfund and RCRA project managers. EPA 542-S-02-001. U.S. Environmental Protection Agency. [19] Loke, M. H. (2014). Tutorial: 2-D and 3-D electrical imaging surveys. Geotomo Software. [20] Dahlin, T., & Zhou, B. (2004). A numerical comparison of 2D resistivity imaging with 10 electrode arrays. Geophysical Prospecting, 52(5), 379–398. https://doi.org/10.1111/j.1365-2478.2004.00423.x [21] Appelo, C. A. J., & Postma, D. (2005). Geochemistry, groundwater and pollution (2nd ed.). A.A. Balkema. [22] Fetter, C. W. (2018). Applied hydrogeology (4th ed.). Waveland Press. [23] Alao, J. O., Lawal, H. A., & Shettima, N. M. (2023). Investigation of groundwater vulnerability to open dumpsites and its potential risk using electrical resistivity and water analysis. Heliyon, 9(2), e13265. https://doi.org/10.1016/j.heliyon.2023.e13265 [24] Alao, J. O., Fahad, A., Abdo, H. G., Ayejoto, D. A., Almohamad, H., Ahmad, M. S., Nur, M. S., Danjuma, T. T., Yusuf, M. A., Francis, O. T., & Joy, A. O. (2023). Effects of dumpsite leachate plumes on surface and groundwater and the possible public health risks. Science of the Total Environment, 897, 165469. https://doi.org/10.1016/j.scitotenv.2023.165469 [25] Badmus, G. O., Ogungbemi, O. S., Enuiyin, O. V., Adeyeye, J. A., & Ogunyemi, A. T. (2022). Delineation of leachate plume migration and appraisal of heavy metals in groundwater around Emirin dumpsite, Ado-Ekiti, Nigeria. Scientific African, 17, e01308. https://doi.org/10.1016/j.sciaf.2022.e01308 [26] Alao, J. O., Otorkpa, O. J., Abubakar, F., Eshimiakhe, D., Aliyu, A., Abdulsalami, M., & Abdulmalik, D. O. (2024). Geoelectrical resistivity and geochemistry monitoring of landfill leachates due to the seasonal variations and the implications on groundwater systems and public health. Scientific Reports, 14, 26542. https://doi.org/10.1038/s41598- 024-77727-6 [27] Zaini, M. S. I., & Hasan, M. (2024). Application of electrical resistivity tomography in landfill leachate detection assessment. In A. Anouzla & S. Souabi (Eds.), A review of landfill leachate: Characterization, leachate environment impacts and sustainable treatment methods (pp. 1–22). Springer. https://doi.org/10.1007/978-3-031-55513-8_1 [28] Godio, A., & Chiampo, F. (2023). Geophysical monitoring of leachate injection in pretreated waste landfill. Applied Sciences, 13(9), 5661. https://doi.org/10.3390/app13095661 [29] May, M. T., Brackman, T. B., May, E. C., & Edwards, W. T. (2024). Use of electrical resistivity tomography to reduce landfill siting risks in the south-central Kentucky karst. Environmental Earth Sciences, 83, 688. https://doi.org/10.1007/s12665-024-11984-6 [30] Moraes, B. Y. M. de, Xavier, F. V., Fachin, S. J. da S., & Netto, L. G. (2023). Application of electrical resistivity tomography for subsurface investigation of a dump in the city of Jaciara-MT. Geologia USP. Série Científica, 23(4). https://doi.org/10.11606/issn.2316- 9095.v23-206488 [31] Piper, A. M. (1944). A graphic procedure in the geochemical interpretation of water-analyses. Transactions, American Geophysical Union, 25(6), 914–928. https://doi.org/10.1029/TR025i006p00914 [32] Gibbs, R. J. (1970). Mechanisms controlling world water chemistry. Science, 170(3962), 1088–1090. https://doi.org/10.1126/science.170.3962.1088 IIARD International Journal of Geography & Environmental Management [33] Schoeller, H. (1962). Les eaux souterraines: Hydrologie dynamique et chimique, recherche, exploitation et évaluation des ressources. Masson et Cie.