The Impact of Varying the Femoral Head Diameter on Stability of Hip Implants

Komonibo, Ernest Bolouebi, Alexander N. Okpala, Tolumoye J. Ajoko

Abstract

Hip Implant failures have increased the number of revision surgeries in recent years due to the effect of dislocation. Hence, remedying the effect of dislocation in Hip Implants is one of the target focus for Biomechanics research scholars. The research investigates how different femoral head diameters impact on stability in complete hip replacement implants. The research used SolidWorks Premium 2025 to create seven hip implant models with Ti-6Al-4V alloy biomaterials and different femoral head diameters from 28mm to 52mm. The implants underwent finite element analysis through ANSYS 2022 R-2 to determine their deformations. The research findings show that deformations decrease when femoral head diameters increase. The 28mm femoral head diameter produced the highest deformation of 0.025918mm, but the 52mm diameter produced the lowest stress of 0.025009mm. Studies have shown that larger femoral head diameters are associated with reduced risk of revision for dislocation and enhances stability. Hence, the research findings are acceptable and shows how different femoral head diameters affect hip implant stability.

Keywords

Femoral Head DiameterHip ImplantFinite Element AnalysisAnsysStabilityDislocation.

References

Wang, L., Trousdale, R. T., Ai, S., An, K. N., Dai, K., & Morrey, B. F. (2012). Dislocation after total hip arthroplasty among patients with developmental dysplasia of the hip. The Journal of arthroplasty, 27(5), 764-769. Berry. D.F (2005). Effect of femoral head diameter and operative approach on risk of dislocation after primary total hip arthroplasty. J Bone Joint Surg (Am), 87, 2456-2463. Byström, S., Espehaug, B., Furnes, O., & Havelin, L. (2003). Femoral head size is a risk factor for total hip luxation A study of 42,987 primary hip arthroplasties from the Norwegian Arthroplasty Register. Acta Orthopaedica Scandinavica, 74(5), 514-524. Jameson, S. S., Lees, D., James, P., Serrano-Pedraza, I., Partington, P. F., Muller, S. D., ... & Reed, M. R. (2011). Lower rates of dislocation with increased femoral head size after primary total hip replacement: a five-year analysis of NHS patients in England. The Journal of Bone & Joint Surgery British Volume, 93(7), 876-880. Witjes, S., Smolders, J. M., Beaulé, P. E., Pasker, P., & Van Susante, J. L. (2009). Learning from the learning curve in total hip resurfacing: a radiographic analysis. Archives of orthopaedic and trauma surgery, 129(10), 1293-1299. Kostensalo, I., Junnila, M., Virolainen, P., Remes, V., Matilainen, M., Vahlberg, T., ... & Mäkelä, K. T. (2013). Effect of femoral head size on risk of revision for dislocation after total hip arthroplasty: a population-based analysis of 42,379 primary procedures from the Finnish Arthroplasty Register. Acta orthopaedica, 84(4), 342-347. Grammatopolous, G., Pandit, H., Kwon, Y. M., Gundle, R., McLardy-Smith, P., Beard, D. J., ... & Gill, H. S. (2009). Hip resurfacings revised for inflammatory pseudotumour have a poor outcome. The Journal of Bone & Joint Surgery British Volume, 91(8), 1019-1024. Langton, D. J., Jameson, S. S., Joyce, T. J., Hallab, N. J., Natu, S., & Nargol, A. V. F. (2010). Early failure of metal-on-metal bearings in hip resurfacing and large-diameter total hip replacement: a consequence of excess wear. The Journal of Bone & Joint Surgery British Volume, 92(1), 38-46. Mokka, J., Mäkelä, K. T., Virolainen, P., Remes, V., Pulkkinen, P., & Eskelinen, A. (2013). Cementless total hip arthroplasty with large diameter metal-on-metal heads: short-term survivorship of 8059 hips from the Finnish Arthroplasty Register. Scandinavian Journal of Surgery, 102(2), 117-123. Seppänen, M., Mäkelä, K., Virolainen, P., Remes, V., Pulkkinen, P., & Eskelinen, A. (2012). Hip resurfacing arthroplasty: short-term survivorship of 4,401 hips from the Finnish Arthroplasty Register. Acta orthopaedica, 83(3), 207-213. Chethan, K. N., Zuber, M., & Satish Shenoy, B. (2019). Finite element analysis of different hip implant designs along with femur under static loading conditions. Journal of Biomedical Physics & Engineering, 9(5), 507 - 516. Milovanović, A., Sedmak, A., Grbović, A., Mijatović, T., & Čolić, K. (2020). Design aspects of hip implant made of Ti-6Al-4V extra low interstitials alloy. Procedia Structural Integrity, 26, 299-305. Bhawe, A. K., Shah, K. M., Somani, S., Shenoy B, S., Bhat N, S., Zuber, M., & KN, C. (2022). Static structural analysis of the effect of change in femoral head sizes used in Total Hip Arthroplasty using finite element method. Cogent Engineering, 9(1), 1-13. IJEMT Dimple, D., Shruti, M., Badgayan, N. D., & Sahu, S. K. (2021). Finite element analysis of hdpe- based hybrid nanocomposite for potential use as liner material for total hip prosthesis. In Advances in Engineering Design: Select Proceedings of FLAME 2020, 305-313. Liu, S., & Shin, Y. C. (2019). Additive manufacturing of Ti6Al4V alloy: A review. Materials & Design, 164, 107552. Sachin, G., & Yogesh, j. (2022). Biomaterials in Hip Joint Replacement. Journal of Engineering Research and Sciences1, 1(8), 01–11.