Insulation Breakdown Strength Under AC and DC Stress Using Different Dielectric Materials: An Empirical Synthesis

Lesuanu Dumkhana, PhD

Abstract

The reliability and efficiency of high-voltage power systems are critically dependent on the performance of insulating materials, which prevent electrical failures by withstanding high voltages. Insulation breakdown occurs when the dielectric strength of a material is exceeded, leading to system faults and reduced operational safety. Despite extensive use of various dielectric materials in transformers, cables, and capacitors, limited empirical data exists on their breakdown behavior under both alternating current (AC) and direct current (DC) stresses, particularly for emerging polymeric and composite insulators. This study aims to empirically determine the breakdown voltages of eight selected dielectric materials under controlled AC and DC conditions, compare their dielectric performance, analyze the influence of stress type on failure mechanisms, and provide practical data for insulation design. Experimental measurements of AC and DC dielectric strengths revealed significant variations among materials. Polyethylene Film exhibited the highest breakdown strength with 500 kV/mm under AC and 600 kV/mm under DC, while Transformer Oil showed 12 kV/mm (AC) and 14 kV/mm (DC). DC stresses consistently resulted in 7–20% higher dielectric strength than AC for all materials. Temperature dependent analysis indicated that breakdown voltages decreased exponentially with increasing temperature, with Transformer Oil dropping from 24 kV at 25°C to 10 kV at 150°C. Safety factor calculations demonstrated that only high-performance insulators such as Polyethylene Film, Epoxy Resin, and Silicon Rubber meet recommended design thresholds under 20 kV operation. Optimal insulation thicknesses were derived using empirical dielectric strengths, revealing that robust materials can reduce insulation requirements by up to 60% compared to conventional oil paper systems. These findings provide quantitative guidance for material selection, insulation coordination, and design policies in high-volta

Keywords

Alternating Currentdirect CurrentdielectricInsulatorsTransformer I.

References

[1] S. Tenbohlen, S. Coenen, M. Djamali, A. Müller, M. Samimi, and M. Siegel, 'Diagnostic Measurements for Power Transformers,' Energies, vol. 9, p. 347, 2016. [2] T. Piotrowski, P. Rozga, and R. Kozak, 'Comparative analysis of the results of diagnostic measurements with an internal inspection of oil-filled power transformers,' Energies, vol. 12, p. 2155, 2019. [3] M. Kunicki, A. Cichon, and S. Borucki, 'Measurements on partial discharge in on-site operating power transformer: A case study,' IET Gener. Transm. Distrib., vol. 12, pp. 2487–2495, 2018. [4] M. Florkowski, M. Kuniewski, and P. Zydro?, 'Measurements and Analysis of Partial Discharges at HVDC Voltage with AC Components,' Energies, vol. 15, p. 2510, 2022. [5] I. Fofana, '50 years of development of insulating liquids,' IEEE Electr. Insul. Mag., vol. 29, pp. 13–25, 2013. [6] D.K. Mahanta and S. Laskar, 'Electrical insulating liquid: A review,' J. Adv. Dielectr., vol. 7, pp. 1730001-1–1730001-9, 2017. [7] U.M. Rao, I. Fofana, T. Jaya, E.M. Rodriguez-Celis, J. Jalbert, and P. Picher, 'Alternative Dielectric Fluids for Transformer Insulation System: Progress, Challenges, and Future Prospects,' IEEE Access, vol. 7, pp. 184552–184571, 2019. [8] P. Rozga, A. Beroual, P. Przybylek, M. Jaroszewski, and K. Strzelecki, 'A review on synthetic ester liquids for transformer applications,' Energies, vol. 13, p. 6429, 2020. [9] Z. Shen, F. Wang, Z. Wang, and J. Li, 'A critical review of plant-based insulating fluids for transformer: 30 years of development,' Renew. Sustain. Energy Rev., vol. 41, p. 110783, 2021. [10] S. Mahmud, G. Chen, I. Golosnoy, G. Wilson, and P. Jarman, 'Experimental studies of influence of DC and AC electric fields on bridging in contaminated transformer oil,' IEEE Trans. Dielectr. Electr. Insul., vol. 22, pp. 152–160, 2015. [11] P. Rozga, M. Stanek, and B. Pasternak, 'Characteristics of Negative Streamer Development in Ester Liquids and Mineral Oil in a Point-to-Sphere Electrode System with a Pressboard Barrier,' Energies, vol. 11, p. 1088, 2018. [12] D. Martin and Z.D. Wang, 'Statistical analysis of the AC breakdown voltages of ester based transformer oils,' IEEE Trans. Dielectr. Electr. Insul., vol. 15, pp. 1044–1050, 2008. [13] V.-H. Dang, A. Beroual, and C. Perrier, 'Comparative study of statistical breakdown in mineral, synthetic and natural ester liquids under AC voltage,' IEEE Trans. Dielectr. Electr. Insul., vol. 19, pp. 1508–1513, 2012. [14] A. Reffas, H. Moulai, and A. Béroual, 'Comparison of dielectric properties of olive oil, mineral oil, and other natural and synthetic ester liquids under AC and lightning impulse stresses,' IEEE Trans. Dielectr. Electr. Insul., vol. 25, pp. 1822–1830, 2018. [15] Working Group A2.35, Experiences in Service with New Insulating Liquids, CIGRE Brochure 436, Paris, France, 2011. [16] X. Wang, Z. Wang, and J. Noakhes, 'Motion of conductive particles and the effect on AC breakdown strengths of esters,' in Proc. 2011 IEEE Int. Conf. Dielectric Liquids, Trondheim, Norway, 26–30 June 2011. [17] A. Beroual, U. Khaled, P.S.M. Noah, and H. Sitorus, 'Comparative Study of Breakdown Voltage of Mineral, Synthetic and Natural Oils and Based Mineral Oil Mixtures under AC and DC Voltages,' Energies, vol. 10, p. 511, 2017. [18] J. Xiang, Q. Liu, and Z.D. Wang, 'Streamer characteristic and breakdown in a mineral oil and a synthetic ester liquid under DC voltage,' IEEE Trans. Dielectr. Electr. Insul., vol. 25, pp. 1636–1643, 2018. [19] Q. Liu and Z.D. Wang, 'Breakdown and withstand strengths of ester transformer liquids in a quasi-uniform field under impulse voltages,' IEEE Trans. Dielectr. Electr. Insul., vol. 20, pp. 571–579, 2013. [20] P. Rozga, M. Stanek, and K. Rapp, 'Lightning properties of selected insulating synthetic esters and mineral oil in point-to-sphere electrode system,' IEEE Trans. Dielectr. Electr. Insul., vol. 25, pp. 1699–1705, 2018. [21] IEC 60897:1987, Methods for the Determination of the Lightning Breakdown Voltage of Insulating Liquids, International Electrotechnical Commission, Geneva, Switzerland, 1987. [22] M.N. Ngoc, O. Lesaint, N. Bonifaci, A. Denat, and M. Hassanzadeh, 'A comparison of breakdown properties of natural and synthetic esters at high voltage,' in Proc. 2010 Ann. Rep. Conf. Electrical Insulation and Dielectic Phenomena, West Lafayette, IN, USA, 17– 20 October 2010. [23] Q. Liu and Z.D. Wang, 'Streamer characteristic and breakdown in synthetic and natural ester transformer liquids under standard lightning impulse voltage,' IEEE Trans. Dielectr. Electr. Insul., vol. 18, pp. 285–294, 2011. [24] G. Dombek, Z. Nadolny, P. Przybylek, R. Lopatkiewicz, A. Marcinkowska, L. Druzynski, T. Boczar, and A. Tomczewski, 'Effect of Moisture on the Thermal Conductivity of Cellulose and Aramid Paper Impregnated with Various Dielectric Liquids,' Energies, vol. 13, p. 4433, 2020. [25] U.M. Rao, I. Fofana, P. Rozga, A. Beroual, J. Malde, R. Martin, F. Wang, E. Casserly, M. Pompili, L. Calcara, et al., 'Next Generation Insulating Liquids,' in Proc. 2022 IEEE 21st Int. Conf. Dielectric Liquids , Sevilla, Spain, 29 May–2 June 2022, pp. 1–4. [26] Mineral insulating oils in electrical equipment - Supervision and maintenance guidance, IEC 60296:2018. [27] E. Kuffel, W. S. Zaengl, and J. Kuffel, High Voltage Engineering: Fundamentals, 2nd ed. Oxford, UK: Newnes, 2012. [28] IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Rotating Machinery Stator Coil Insulation, IEEE Standard 286-2000, 2000. [29] Electric strength of insulating materials - Test methods - Part 1: Tests at power frequencies*, IEC 60243-1:2013.

More Articles from WORLD JOURNAL OF INNOVATION AND MODERN TECHNOLOGY