Reducing Corrosion of Carbon Steel Pipes using Cathodic Protection with Anode Separation: A Case Study of Nembe Creek Flow Station

AMALAGHA, Patience Sekegha , Isaac O. E. and Nkoi B. , Amadi R .K .C and Ugoji K. U.

Abstract

This research seeks to reduce corrosion using cathodic protection with anode separation for the pipeline structures in Nembe Creek Flow Station. . Sacrificial anode and impressed current cathodic protection current demands of offshore X42 steel pipeline with 1.5m diameter and 100km length, and the onshore X65 steel pipeline with 1.0m diameter and 80km length, located in Niger Delta region spanning from Delta to Bayelsa State in Nigeria was determined using the data of the design parameters for the pipeline, anode and environment collected from NNPC/PPMC and by employing relevant Sacrificial Anode Cathodic Protection and Impressed Current Cathodic Protection methods respectively 4147440mA was estimated as 8381 anodes while 4839 anodes separated at a distance of 16.5m proportionally along the entire onshore pipeline length, are required to meet 35 years intended design life of the onshore pipeline

Keywords

corrosionsacrificialanodecathodic and onshore.

References

Ameh, E. S. & Ikpeseni, S. C. (2017). Pipelines Cathodic Protection Plan Methodologies for Impressed Current and Sacrificial Anode System, Nigeria Journal of Technology, 36(4): 1072 – 1077. Bushman, J. B. (2012). Corrosion and Cathodic Protection Theory, Bushman Associate Inc, Medina, Ohio. Dwight, H. B. (1936) Calculation of Resistance to Ground, Electrical Engineering, 55(12), 1319 – 1329. El-Alem, A. I., Azmy, A. M. & Hosam-Eldin, A. (2013). Plan of a Cathodic Protection System to Prevent Corrosion of Metallic Structure using Hybrid Renewable Energy Sources. Engineering Research Journal 36(12), 109-117. Emmanuel, J. E., Emmanuel, J., Akpabio, E. J. & Ubong, I. E. (2012) Cathodic protection of buried steel oil pipelines in Niger Delta. International Journal of Advances in Engineering, Science and Technology, 6(4) 304-307. Guyer, J. P. (2009). Introduction to Cathodic Protection. Continuing Education and Development Lecture Notes, Continuing Education and Development Inc. 22. Iseru, E., Fagbemi, E., Awolola, K., Akpovwovwo, T. (2014) Mitigating External Corrosion Failures in Buried Petroleum Pipelines in Nigeria: A Review. International Journal ofEcological Science and Environmental Engineering. 1(2), 67-72 Lilly, M. T., Ihekwoabaa, S. C., Ogaji, S. O. T. & Probert, S. D. (2007) Prolonging the lives of buried crude-oil and natural-gas pipelines by cathodic protection. Applied Energy, 84(9), 958 – 970. Mohammed, O. M., Omar, T., Racid, Z., Saida, B. & Cari, D. (2014) Corrosion Induced by High Voltage Powerline on Cathodically Protected Pipeline, International Conference on Control, Engineering and Information Technology – proceeding, IPCO. Onyekpe, B. (2002) Corrosion in Oil and Gas Production. Ambik Press: Benin City. Unueroh, U., Omonria, G., Efosa, O. & Awotunde, M. (2016). Pipeline Corrosion Control in Oil and Gas Industry: A Case Study of NNPC/PPMC System 2A Pipeline. Nigerian Journal of Technology 35(2): 317-320.

More Articles from INTERNATIONAL JOURNAL OF ENGINEERING AND MODERN TECHNOLOGY