International Journal of Engineering and Modern Technology (IJEMT )
E-ISSN 2504-8848
P-ISSN 2695-2149
VOL. 10 NO. 5 2024
DOI: 10.56201/ijemt.v10.no5.2024.pg50.64
Popoola Olateju Ebenezer and Mgbonu Kelechi
A centrifugal fan for chemical application in orchard farm, producing air stream with a maximum value of 9.81 m/s was developed and its performance evaluated in the research. The fan performance was evaluated with three parameters, namely: linear velocity (air velocity), fan output power and mechanical efficiency. The fan input power or the shaft power was obtained at different sheave diameters of 110, 130, 150 and 190 mm using established relationships. The fan parameters obtained were subjected to analysis of variance in order to determine if there were significant differences between these parameters at the selected sheave diameters at 95 % confidence level. Findings of the research revealed that the fan input power ranged from 1.2039 to 3.16 kW; the analytical fan output power ranges from 0.0043 to 0.0161 kW; the air velocity ranged from 7.73 to 9.81 m/s; while the airflow rates ranged from 0.0043 to 0.0161 m3/s. The developed centrifugal fan has a maximum of 68.42 % mechanical efficiency, and capable of delivering air stream at a velocity of 9.81 m/s. The calculated parameters were significant at 95 % confidence level at different sheave diameters. The centrifugal fan was found suitable for chemical application in orchard protection operations.
Air flow velocity, Centrifugal fan, fan output power, Mechanical efficiency
Ananthemarayanam P. N. (2015). Basic Refrigeration and Air Conditioning (Fourth Edition).
Tata Mc. Graw-Hill Publishing Co. Ltd. New Delhi, India.
BEE (2010). Fans and Blowers. Bureau of Energy Efficiency. R. K.Puram, New Delhi – 110066.
India. Pp 93-112.
Cevik, F. (2010). Design of an axial flow fan for a vertical wind tunnel for paratroopers.
Unpublished M.Sc. Thesis Submitted to the Graduate School of Natural and Applied
Sciences, Middle East Technical University.
Doruchowski, G., Swiechowski, W., Godyn, A. and Holownicki, R.(2011). Automatically
controlled sprayer to implement spray drift reducing application strategies in
orchards. Journal of Fruit and Ornamental Plant Research, 19 (4): 175–182.
Osterman, A., Godesa, T. and Hocevar, M. (2014).Canopy adapted orchard spraying. Proceeding
of the 42nd International Symposium on Agricultural Engineering. Pp 179-189.
Severns, W. H and Fellows, J. R. (1998). Airconditioning and refrigeration. John Wiley andSons
Inc., London.
Singh, O. P., Rakesh, K. T. and Sreenivasulu, M. K. (2011). Parametric study of centrifugal fan performance: experiments and numerical simulation. International Journal of Advances in Engineering & Technology,1 (2): 18.
Uffe, H., John, R. Z., Bruce, R. H., Ralph, J. E., Wendell, C. H. and John, D. L. (1983). Machine
design fundamental. A practical approach.Pp.416-422.
UNEP (2006). Electrical energy equipment. energy efficiency guide book 2004. United Nation
Environment Programme. Energy Efficiency Guide for Industry in Asia, India. Pp.93-112.