INTERNATIONAL JOURNAL OF MEDICAL EVALUATION AND PHYSICAL REPORT (IJMEPR )
E-ISSN 2579-0498
P-ISSN 2695-2181
VOL. 8 NO. 4 2024
DOI: https://doi.org/10.56201/ijmepr.v8.no4.2024.pg63.75
Shatha F. Murad
The purpose of this research was to examine the effects of medical radiation on human cells, namely lymphocytes. We analyzed the frequency of chromosomal abnormalities in cells exposed to X-ray photon irradiation at 6 and 10 MV, with dose rates ranging from 5.50 to 23.08 Gy/min and absorbed doses ranging from 0.5 to 8 Gy. For the sake of comparison, a 60Co curve was used. Standard cytogenetic procedures were used to produce metaphases from the cell cultures, and chromosomal analysis was carried out. Based on our findings, biodosimetry may be carried out using doses and energy that are greater than those of the reference dose presently in use. We found that the aberration frequencies varied significantly across the various irradiation methods. The radiobiological impact is stronger in FFF mode compared to FF mode. A linearquadratic dose response calibration curve was built to determine the relative biological effectiveness (RBE). The average RBE values for 60Co ? irradiation were 1.28, for 6 FFF they were 1.11, and for 10 FFF they ranged from 0.79 to 0.92, all caused by the reference radiation, which is 6MV (5.50 Gy/min). These findings might be even more significant in a therapeutic context due to the significant variations across radiation modalities in hypofractionation situations. In the event of a patient's unintentional overdose, it is crucial to quantify the overdose using the proper calibration curves for biodosimetry.
Radiation, Biological, Cell, Lymphocyte
IAEA-International Atomic Energy Agency. Cytogenetic analysis for radiation dose
assessment. Technical report series. Vienna2001.
Koksal G, Pala FS, Dalci DO. In vitro dose-response curve for chromosome aberrations
induced in human lymphocytes by 60Co gamma-radiation. Mutat Res
1995;3291:57–61.
Rungsimaphorn B, Rerkamnuaychoke B, Sudprasert W. Establishment of dose-
response curves for Dicentrics and premature chromosome condensation for
radiological emergency preparedness in Thailand. Genome Integr 2016;7:8.
Lemos-Pinto MM, Cadena M, Santos N et al. A dose-response curve for biodosimetry
from a 6 MV electron linear accelerator. Braz J Med Biol Res 2015;4810:908–
14.
Zubizarreta EH, Poitevin A, Levin CV. Overview of radiotherapy resources in Latin
America: A survey by the International Atomic Energy Agency (IAEA).
Radiother Oncol 2004;731: 97–100.