RESEARCH JOURNAL OF PURE SCIENCE AND TECHNOLOGY (RJPST )

E-ISSN 2579-0536
P-ISSN 2695-2696
VOL. 5 NO. 2 2022
DOI: https://doi.org/10.56201/rjpst.v5.no2.2022.pg56.66


Gasoline Generators and their Effects on Air Quality of Some Selected Business Centers in Tertiary Institutions in Rivers State

Robert, James J., Dibia, Victor O.


Abstract


This study considered gasoline generators and their effects on air quality of some selected business centers in tertiary institutions in Rivers State. Air quality monitor was positioned 1.5m above the floor to determine the concentration levels of CO, CO2 and O2. The measurements were done on a daily for a period of three weeks. At FCE (T), Omoku, the mean concentration values of CO for Business and Institution’s generators were 109.2ppm and 62.3ppm; CO2 283.6ppm and 27.4ppm and O2 185.8% and 192.1% respectively. At IAUE, Port-Harcourt, CO for Business and Institution’s generators had mean concentration values of 144.7ppm and 89.6ppm; CO2 210.9 ppm and 188.8ppm, and for O2, 225.4% and 239.2% respectively. Similarly, for RSU, Port-Harcourt, the mean concentration of CO for Business and Institution’s generators were 144.8ppm and 84.5ppm; CO2 171.1ppm and 124.ppm; and for O2, 196.8% and 164.3%. respectively. CEAP, Port-Harcourt, CO had mean concentration values of 215.3ppm and light 92.2ppm, CO2 226.2ppm and 109.2ppm, whileO2 mean concentration values of 120.1% and 198.2% respectively. The concentration levels of CO, CO2 for business generators were much higher compared to when Institutions’ generators were used. The mean values of CO concentrations for the selected institutions for the period under study were higher than OSHA permissible exposure limit (PEL) of 50ppm (55mg/m3), NIOSH recommended exposure limit (REL) of 35ppm (40 mg/m3) and ACGIH threshold limit value (TLV) of 25ppm (28.6mg/m3), while that of CO2 concentration levels were less than OSHA’s established permissible limit of 5000ppm, and American Conference of Governmental Industrial Hygienists(ACGIH) threshold limit value (TLV) of 25ppm. It was also observed that as the concentrations of CO and CO2 increase, the O2 levels also decrease. It is therefore, very important to state that tertiary institutions’ managements in Nigeria should consider the provision of regular power supply on


keywords:

Gasoline generator, Effects, Air Quality, Business Centers


References:


Lawal, A., Lateef, K & Zubair, O. (2020). Analysis of environmental effects of the major stand-
alone power generators used in Nigeria and Sub-saharan Africa. ATBU Journal of
Environmental Technology, 13 (2), 14 - 27. 10.13140/RG.2.2.34879.64168.

Akin, A. O., & Adejumobi, D. O. (2017). Domestic electric power generator usage and residents
livability Milieu in Ogbomoso, Nigeria. Environmental Management and Sustainable
Development, 6(1), 91.

Azuma, K., Kagi, N., Yanagi, U & Osawa, H. (2018). Effects of low-level
inhalation exposure to carbon dioxide in indoor environments: A short review on human
health and psychomotor performance. Environment International,121(Pt 1), 51-56.
10.1016/j.envint.2018.08.059

Boston University School of Public Health. (2017). Respiratory health. https://sphweb.bumc.bu.
edu/otlt/MPH-Modules/PH/RespiratoryHealth/RespiratoryHealth7.html

Blumenthal, I. (2001). Carbon monoxide poisoning. Journal of the Royal Society of Medicine,
94(6), 270–272. doi: 10.1177/014107680109400604

Brasted, R. C. (2017, November 3). Oxygen group element. Encyclopedia Britannica.
https://www.britannica.com/science/oxygen-group-element

Cameo Chemicals. (n.d). Chemical Datasheet. https://cameochemicals.noaa.gov/chemical/8967
Chawre, A. (n.d ). Benefits of Air Quality Monitoring. https://www.ppsthane.com/blog/benefits-
of-air-qualitymonitoring#:

CDC. (2019). Carbon monoxide. https://www.cdc.gov/niosh/npg/npgd0105.html


DOWNLOAD PDF

Back