INTERNATIONAL JOURNAL OF CHEMISTRY AND CHEMICAL PROCESSES (IJCCP )

E-I SSN 2545-5265
P- ISSN 2695-1916
VOL. 8 NO. 1 2022
DOI: https://doi.org/10.56201/ijccp.v8.no1.2022.pg34.64


Comparative Studies on Spectrophotometric Determination of Selected Heavy Metals in Environmental and Biological Samples with Synthetic Phenylhydrazones as Chromogenic Reagents

Echioda Samuel, Chindo I. Y. and Kolo A. M. Salisu Salisu


Abstract


This work involves a comparative study on a simple, sensitive, selective and non-extractive Uv- Vis spectrophotometric method for the determination of cadmium, lead, chromium and arsenic in biological, soil and water samples using synthesized and characterized phenylhydrazones; [glutaraldehyde phenylhydrazone (GPH) and acetylpyridine-2,4-dinitrophenylhydrazone (APDH)] as the chromogenic reagents was developed. GPH and APDH were synthesized as new chromogenic analytical reagents for the direct UV-Vis spectrophotometric determination of the selected metals of interest in a slightly acidic pH of 6.5-7.5 and 20% dimethylformamide (DMF) solution to give stable coloured metal-ligand complexes. The reactions were instantaneous; the wavelengths of maximum absorptions were followed spctrophometrically and noted. The analytical properties of the reagent APGH on the metals (Cd, As, Pb, and Cr) revealed the wavelength of maximum absorption ranged between 385.0 (Cr) to 440.0nm for (Pb). The reagent APDH had molar absorptivities (L mol -1 cm -1 ) ranging from 2.006 x 10 4 (Pb) to 2.407 x 10 4 (Cd), a mole ratio of metal to ligand of 1:1, a detection limit (µg/g) ranging from 0.3272 (As) to 0.4456 (Cd) and the metal-ligand complex was stable for 0-36 hours. The reagent GPH revealed a wavelength of maximum absorption between 360.0 (Cr) to 395.0 nm for (Pb and As) at a working pH of 6.5 to 7.5 room temperature (37°C). The reagent GPH had a molar absorptivities (L mol -1 cm -1 ) ranging from 2.213 x 10 4 (Pb) to 2.460 x 10 4 (As), a mole ratio of metal to ligand of 2:1, the detection limit (µg/g) ranging from 0.3432 (As) to 0.5250 (Pb) and the metal-ligand complex was stable for 0-48 hours. Both reagents had a Beer’s law validity range (mgL -1 ) of 0.001 to 100. The Sandell’s sensitivities (µg/cm 2 ) ranged from 0000409 (As) to 0.00499 (Pb) for APDH and 0.00406 (As) to 0.00452 (Pb) respectively. Large excess of cations and anions as possible interferences up to 1


keywords:

Simple, sensitive, selective, non-extractive, Uv-Vis spectrophotometric, phenyl- hydrazone, heavy metals.


References:


Adi, N., Reddy, S. K., Janardhan, R., Lee, K. D. and Varada, R. (2012). Evaluation of 2, 6-
diacetylpyridinebis-4-phenyl-3-thiosemicarbazone as complexing reagent for arsernic, lead
and cadmium in food and environmental samples, Journal of Saudi Chemical Society. 20,
1-9.
Ahmed, A., Fkruddin, M. D. and Lingappa, G. A. (2011). Arsenic, Chromium and Lead in
Enviromental and Biological Samples Using 2, 5- thiophenedicarboxaldehyde
thiosemicarbazone. International journal of Chemistry Research. 2, 72-75.
Azhar, A. G. (2015). Spectrophotometric Determination of Silver (I) and Chromium (VI) by
using 2-[(6-Nitro-2-Benzothiazolyl)]-4,5-diphenyl imidazole as Analytical reagent.
International Chemistry Journal of Iran. 7(2), 451-453.
Cristofol, E., Sanchez, F., Rojas, E. and Cano-Pavon J. M. (2001). Evaluation of Various N-
Phenylthiosimecarbazones as Chromogenic Reagents in Spectrophotometric Analysis.
Talanta. 38(4), 445-448.
Deepa, K.Y., Paul, R. and Lingappa, Y. ( 2014). Spectrophotometric determination of lead in
medicinal
leaf
and
enviormental
samples
using
5-methylthiophene-2-
carbaxaldehydeethylenediamine (MTCED). Journal of Der Pharmacia Lettre 6(6), 380-
388.

Fakruddin, A., Ahmed, M. D., LIngappa, Y. and Glory, A. (2011). Spectrophotometric
determination of Arsenc, Lead, in Enviromental and Biological Samples Using 2,5-
Thiophenedicarboxaldehydethiosemicarbazones. International Journal of Chemistry
Research. 2(3), 72-75.
Gopala, D., Krishna, N., Devanna, F. and Chandrasekhar, K. (2010). Comparative study of
Polladium (II) using 4-hydoxy 3,5-dimethoxy benzldehydeCinnamaldehyde 4-hydroxy
benzalhydrazone in presence of micellar medium by spectrophotometry, International
journal of Pharmaceutical Sciences and Research (IJPSR). 1(8), 301-311.
Humaira, K., Jamaluddin, M., Ahmed, A. and Bhanger, M. (2009). A Simple spectrophotometric
method for the determination of trace levels of lead in Biological samples in the presence
of aqueous micellar solution, Journal of spectroscopy. 20, 285-297.
Kalshetly, F. Y. (2011). Synthesis and rapid determination of mercury, colbalt, chrominm and
arsernic in Plant and Soil Samples Using Inductively Coupled Plasma Atomic Emission
Spectroscopy, a Comparative Study. Water, air and soil pollution Journal. 170(1-4),
161–171.
Katyal, D. O. (2005). Simultaneous pre-concentration procedure for the determination of
cadmium and lead in drinking water employing sequential multi-element flame atomic
absorption spectrometry. International Journal of Enviromental Analytical Chemistry.
91, 1425-1435.
Krishna, G. D. and Devi, C. H. (2012). Determination of lead in Presence of Micellar Medium
using
4-hydroxy-3,5-dimethoxy-benzaldehyde-4-hydroxybenzoyl
hydrazone
by
Spectrophotometry. International Journal of Chemical Science and Technology. 2(2),
29-31.
Krishna, G. D., Rekha, D., Suvardhan, K., Kumar, K. S., Reddyprasad, P., Jayaraj, B. and
Chiranjeevi, P. (2011). Spectrophotometric determination of cadium in water and alloy
samples with 3-methoxy-4-hydroxybenzaldehyde-4-bromophenyl hydrazone. Journal of
Serbia Chemical Society.72(3), 299–310.
Jamaluddin, M. A. and Shah, M. A. (2003). A rapid spectrophotometric method for the
determination of mercury in environmental, biological, soil and plants samples using
diphenylthiocarbazone. Journal of spectroscopy. 17, 45-52.
Jamaluddin, M. A. and Tasnima, Z. (2012). A Simple Spectrophotometric Method for the
determination of Copper in Some Real Enviromental, Biological, Food and Soil Samples
Using Salicyaldehyde Benzoyl Hydrazone. Pakistan Journal of Analytical and
Enviromental Chemistry. 13(1), 22-35.
Jamaluddin, M. A., Tasnima, Z. and Zannatul, F. (2014). A simple spectrophotometric method
for the determination of trace level cadmium in real, environmental, biological tobacco,


DOWNLOAD PDF

Back